• s_banner

Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for portable bone density, Bone Densitometer Adalah, Bone Densitometry History, Good quality is factory' existence , Focus on customer' demand is the source of company survival and advancement, We adhere to honesty and superior faith working attitude, hunting forward towards your coming !
Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan Detail:

Bmd-A3 is a portable ultrasonic bone density instrument for measuring bone density. The device could be used for disease diagnosis, or for disease screening and physical examinations in healthy people. Ultrasonic bone density instrument than DEXA bone density instrument cost-effective, simple operation, no radiation, high precision, less investment. A bone density test, sometimes called a bone density test, can detect if a patient has osteoporosis.

When you have osteoporosis, your bones become weak. They become more prone to rupture. Bone joint pain and fracture caused by osteoporosis are common clinical diseases, such as lumbar deformation, intervertebral disc disease, vertebral body fracture, cervical spondylosis, limb joint and bone pain, lumbar spine, femoral neck, radial fracture, etc. Therefore, bone mineral density examination is very necessary for the diagnosis and treatment of osteoporosis and its complications.

Main Function

Densitometry is a measure of the bone density or strength of the radius and tibia in a person. This is a good way to prevent osteoporosis.

It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.

BMD-A3-3
BMD-A3-1

Application

BMD-A3 device is the best choice for hospital pre-discharge examination, ward, mobile examination, physical examination, pharmaceutical, pharmacy, health product promotion.

Application Range

Ultrasonic bone mineral density measurement is applied in: maternal and child health care center, geriatric hospital, sanatorium, rehabilitation hospital, bone injury hospital, physical examination center, health center, community hospital, pharmaceutical factory, pharmacy, health care product promotion, etc.
The Department of the General Hospital, Such as

Pediatric Department,

Gynecology and Obstetrics Department,

Orthopedics Department,

Geriatrics Department,

Physical Examination Department,

Rehabilitation department

Physical Examination Department

Endocrinology Department

Advantages

Ultrasonic bone density measurement has low investment and high benefit.

The advantages are as follows:

1. Less investment

2. Very high utilization rate

3. Small footprint

4. Quick return, no consumables

5. High returns

6. Measurement sites: radius and tibia.

7. The probe adopts American DuPont technology

Measurement Parts: Radius and Tibia.

image8
image9

Operational Principle

image10
image11
image12

Main Feature

● Portable and convenient, flexible movement

● Precision, beautiful

● All dry technology, convenient diagnosis.

● Measurement sites: radius and tibia.

● The measurement process is quick, simple and fast

● High measurement efficiency, short measurement time

● High accuracy of measurement

● Very good reproducibility measurement

● Unique correction system, effective correction system error.

● There are clinical databases in different countries, including: Europe, America, Asia, China

● Strong international compatibility. It measures coverage for people between the ages of 0 and 120. (Children and adults)

English menu and color printer report, easy to operate

●CE, ISO, CFDA, ROHS, LVD, EMC certification

Technical Specifications

image1 Large Scale Integrated circuit

image2 Multi – layer circuit board design

image3 High shielding Multi-point Signal Contact Mode

image4 Precise Mould Manufactured

image5 Famous Brand Embedded Industrial Control Computer

image6 Special Analysis System Based on Different Countries People

Bone Density Testing Results

BMD results can be scored in two ways:

T-value: This means comparing your bone density with that of a healthy young person of the same sex. This score indicates that your bone density is normal, below normal, or indicates a level of osteoporosis.

Here are the interval values for T scores:
●-1 and above: normal bone density
●-1 ~ -2.5: Low bone density, which may lead to osteoporosis
●-2.5 and above: osteoporosis

Z-score: This allows you to compare the bone mass of people of your age, sex and size.
A Z value below -2.0 means you have less bone mass than others your age, which can be due to reasons other than age.

Configuration

1. BMD-A3 Ultrasound Bone Densitometer Main Unit

2. 1.20MHz Probe

3. Famous Brand Embedded Industrial Control Computer

4. BMD-A3 Intelligent Analysis System

5. Calibrating Module (Perspex sample)

6. Disinfectant Coupling Agent

Note: Printer is optional

One Carton

Size(cm): 46cm×35cm×50cm

G.W.: 13Kgs

N.W.: 6 Kgs

Note: Printer is optional

BMD-A1-(2)

Densitometry is a measure of the bone density or strength of the radius and tibia in a person. This is to prevent osteoporosis. Human bone mass starts to decline irreversibly from the age of 35. A bone density test, sometimes called a bone density test, tests if you have osteoporosis and measures how much calcium and minerals are in your bones. The more minerals in your bones, the better. This means your bones are stronger, denser and less likely to break. The lower the mineral content, the greater the chance of breaking a bone in a fall. Osteoporosis can happen to anyone.

When you have this disease, your bones become weak. They become more prone to rupture. It’s a silent state where you don’t feel any symptoms. Without a bone density test, you may not realize you have osteoporosis until you break a bone.

image14

Bone Health(left)                                                                                    Osteopenia(middle)                                                                                    osteoporosis(right)  

Packing

A3-packing-(3)
A3-packing-(2)
A3-packing-(5)
A3-packing-(4)


Product detail pictures:

Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan detail pictures

Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan detail pictures

Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan detail pictures

Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan detail pictures

Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan detail pictures


Related Product Guide:

Our firm aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine regularly for Renewable Design for Bone Densitometry Screening - Portable Ultrasound Bone Densitometer BMD-A3 – Pinyuan , The product will supply to all over the world, such as: Yemen, Liberia, Egypt, Our company promises: reasonable prices, short production time and satisfactory after-sales service, we also welcome you to visit our factory at any time you want. Wish we have a pleasant and long terms business together!!!
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Mag from USA - 2018.07.26 16:51
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Riva from Riyadh - 2018.02.12 14:52