• s_banner

OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We are commitment to offer you the aggressive price tag ,exceptional products and solutions high-quality, as well as fast delivery for Bone Densitometry Whole Body, Bone Densitometry Price, Tibia Bone Densitometer, At our firm with good quality initially as our motto, we manufacture merchandise that are entirely made in Japan, from materials procurement to processing. This enables them for being used with confident peace of mind.
OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan Detail:

Application

Dual-Energy X-ray Absorptiometry (DXA or DEXA) using a very small dose of ionizing radiation to produce pictures of the inside of the forearm to measure bone density . It is evaluating for Osteoporosis and Osteopenia and provides a versatile solution for evaluating the risk of osteoporotic fracture.

It is an enhanced form of X-ray technology that is used to measure bone loss. DXA is today’s established standard for measuring bone mineral density (BMD).

Measuring--the-Front-of-Forearm-

Features

Using digital Laser Beam Positioning Technique.

Special Analysis System Based on Different Countries People.

Using the Most Advanced Cone – Beam and Surface Imaging Technology.

Measurement Parts: the Front of Forearm.

With High Measurement Speed and Short Measurement Time.

Adopting the Full Closed Lead Protective Window to Measure.

Details Display

800F-English-4

Protecting Mask

800F-English-5

Using digital Laser Beam Positioning Technique

Technical Specifications

Large Scale Integrated Circuit.

Multi -Layer Circuit Board Design.

Light Source Technology With High Frequency and Small Focus.

Imported High Sensitivity Digital Camera.

Using the Cone – Beam and Surface Imaging Technology.

Using Laser Beam Positioning Technique.

Using the Unique Algorithms.

ABS Mould Manufactured, Beautiful, Strong and Practical.

Special Analysis System Based on Different Countries People.

Technical Parameter

1.Using the Dual Energy X-ray Absorptimetry.

2.Using the Most Advanced Cone – Beam and Surface Imaging Technology.

3.With High Measurement Speed and Short Measurement Time.

4.With Dual Imaging Technology to Get More Accurate Measurement.

5.Using Laser Beam Positioning Technique, Making the Measuring Position More Accurate.

6.Dectcing Image Digitization, to Get Accurate Measurement Results.

7.Adopting the Surface Imaging Technology, Measuring Faster and Better.

8.Using the Unique Algorithms to Get More Accurate Measurement Results.

9.Adopting the Full Closed Lead Protective Window to Measure, only Need to Put the Patient’s Arm into the Window. The Equipment is Indirect Contact with the Scanning Parts of the Patient. Easy to Operate for the Doctor. It is Safety for the Patient and Doctor.

10.Adopting Integrated Structure Design.

11.Unique Shape, Beautiful Appearance and Easy to Use.

Performance Parameter

1.Measurement Parts: the Front of Forearm.

2. X ray tube voltage: High Energy 70 Kv, Low Energy 45Kv.

3.The high and low energy corresponds to the current, 0.25 mA at high energy and 0.45mA at low energy.

4.X-Ray Detector: Imported High Sensitivity Digital Camera.

5.X-Ray Source: Stationary Anode X-ray Tube (with High Frequency and Small Focus).

6.Imaging Way: Cone – Beam  and Surface Imaging Technology.

7.Imaging Time: ≤ 4 Seconds.

8.Accuracy(error)≤ 0.4%.

9.Repeatability Coefficient of Variation CV≤0.25%.

10.Measuring Area :≧150mm*110mm.

11.Can be connected to hospital HIS system, PACS system.

12.Provide Worklist Port with independent upload and download function.

13.Measuring Parameter: T- Score, Z-Score, BMD, BMC, Area, Adult percent[%], Age percent[%], BQI (The Bone Quality Index) ,BMI、RRF: Relative Fracture Risk.

14. It with multi race clinical database, including: European, American, Asian, Chinese, WHO international compatibility. It measuring the people between the age of 0 and 130.

15.Measuring children over three years older.

16.Original Dell Business Computer: Intel i5, Quad Core Processor 8G 1T 22’inch HD Monitor.

17.Operation System: Win7 32-bit / 64 bit ,Win10 64 bit compatible.

18.Working Voltage: 220V±10%, 50Hz.

Who Should Get Bone Density Tested

Anyone can get osteoporosis. It’s more common among older women, but men can have it, too. Your chances increase as you age.
● You should discuss with your doctor whether you need the DXA Bone Test. They may recommend it if you meet any of the following:You’re a woman 65 or older.
● You’re a postmenopausal woman 50 or older.
● You’re a woman at the age of menopause and have a high chance for breaking bones.
● You’re a woman who has already been through menopause, younger than 65, and have other things that give you a higher chance of osteoporosis.
● You’re a man 50 or older with other risk factors.
● You break a bone after 50.
● You’ve lost more than 1.5 inches of your adult height.
● Your posture has gotten more hunched.
● You’re having back pain without any cause.
● Your periods have stopped or are irregular although you’re neither pregnant nor menopausal.
● You’ve gotten an organ transplant.
● You’ve had a drop in hormone levels.

Some types of prescription drugs can cause bone loss. These would include glucocorticoids, a class of drugs used to reduce inflammation. Tell your doctor if you’ve been on cortisone (Cortone Acetate), dexamethasone (Baycadron, Maxidex, Ozurdex), or prednisone (Deltasone).

Our DXA Bone Densitometry is  for the Peripheral testThis measures bone density at your the front of forearm.  It is usually cheaper.

Peripheral tests are also a way to screen people, so those who show a greater chance for osteoporosis can get more testing. They are also used for larger people who cannot get the central DXA because of weight limits.

The results on the bone density report
T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.

Here’s what the T score means:
● -1 and above: Your bone density is normal.
● -1 to -2.5: Your bone density is low, and it may lead to osteoporosis.
● -2.5 and above: You have osteoporosis.

Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.


Product detail pictures:

OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures


Related Product Guide:

We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for OEM Supply Dual Energy X Ray Absorptiometry Research Equipment - DEXA Bone Densitometry DXA 800E – Pinyuan , The product will supply to all over the world, such as: Kazakhstan, Burundi, Mozambique, If any product meed your demand, please feel free to contact us. We're sure your any inquiry or requirement will get prompt attention, high-quality products, preferential prices and cheap freight. Sincerely welcome friends all over the world to call or come to visit, to discuss cooperation for a better future!
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Constance from Mexico - 2017.12.09 14:01
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Grace from Mongolia - 2017.09.29 11:19