• s_banner

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Dependable good quality and very good credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality initial, shopper supreme" for Bone Mass Measurement, Bone Densitometer Machine Price, Dual Energy Xray Absorptiometry Definition, By more than 8 years of company, now we have accumulated rich experience and advanced technologies from the generation of our merchandise.
Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan Detail:

Advantages Of Our Bone Density Machine

1.Safe for the measurement of younger or pregnant person, with non-invasive nature of ultrasound

2.Approx 15 seconds per measurement, suitable for screening test for osteoporosis

3.Early Assessment of Osteoporosis

4.No need for the patient to undress

5.Ultrasound test, No ionizing radiation

6.Scan can be performed by any trained operator

7.Immediate printed report

8.Most affordable, clinical test for osteoporosis

NEW--A1-(2)

Technical Features

1. Measurement parts: radius and Tibia.

2. Measurement mode: double emission and double receiving.

3. Measurement parameters: Speed of sound (SOS).

4. Analysis Data: T- Score, Z-Score, Age percent[%], Adult percent[%], BQI (Bone quality Index ), PAB[Year] (physiological age of bone), EOA[Year] (Expected Osteoporosis age), RRF(Relative Fracture Risk). BMI.

5. Measurement Accuracy : ≤0.3%.

6. Measurement Reproducibility: ≤0.3%.

7. Measurement time: .

8. Probe frequency : 1.20MHz.

9. Date analysis : it adopt a special intelligent real –time data analysis system, it selects the adult or child databases according to the age automatically.

10. Temperature control: Perspex sample with temperature instructions.

11. Probe crystal indication: it display the working condition for the four crystal of the probe, and the signal strength for the ultrasonic reception.

12. Daily Calibration: automatic calibrating after power on.

13. All the people of the world. It measuring the people between the age Of 0 and 100,(Children: 0-12 years old, Teenagers: 12-20 years old, Adults:20-80 years old, The Elderly 80-100 yeas old, only need to input the age and recognizing automatically.

14. Temperature display calibration block: the calibration with pure copper and Perspex, the calibrator display current temperature and standard SOS. The equipment leave the factory with Perspex sample.

15. Repot mode: color.

16. Report format: supply A4, 16K ,B5 and more size report.

17. With HIS , DICOM, database connectors.

18. Computer configuration: original Dell business configuration: G3240, dual core, 4G memory, 500G hard disk, original Dell recorder., wireless mouse.

19. Computer Monitor: 20’ color HD color LED monitor.

Configuration(Assembly)

1. BMD-A1Ultrasound Bone Densitometer Main unit

2. 1.20MHz Probe

3. BMD-A1 Intelligent Analysis System

4. Luxurious Trolley

5. Dell Business Computer

6. Dell 19.5 Inch Color LED Monitor

7. Canon Color Ink Jet Printer IP2780

8. Calibrating Module (Perspex sample)

9. Disinfectant Coupling Agent

Measurement Parts: Radius and Tibia.

image8

Testing the bone density of Tibia

image5

Measuring the bone density of radius

How Are The Results Of A Bone Mineral Density Test Assessed?

Bone mineral density tests are interpreted by medical imaging specialists called radiologists. The radiologist will send a report back to the doctor who referred you.

The radiologist will calculate 2 scores to help interpret your bone mineral density test: a T score and a Z score.

● T score. This indicates how dense your bone is compared to what would be expected in a young healthy adult of your sex. Your T score is the number of units — standard deviations (SD) — that your bone density is above or below the young healthy average.

The more negative the T score, the thinner your bones and the more likely they are to break easily. A T score above -1 is considered normal, between -1 and -2.5 is considered osteopenia (low bone mass) and -2.5 or a more negative score is considered osteoporosis.

image7

● Z score. This compares your bone density to that of other people your age, sex and race. Your Z score should be between -2 and +2. A Z score more negative than -2 (e.g. -2.5) could indicate that you are losing bone for a reason unrelated to age, so your doctor will probably want to do further investigations.

What If My Bone Mineral Density Test Is Abnormal?

If your bone mineral density test is abnormal, indicating osteopenia or osteoporosis, you should discuss the results with your doctor. He or she may want to do further investigations such as blood tests to look for conditions that might be contributing to bone loss, or an X-ray to see whether any fractures are already present. The good news is that you can take steps to improve your bone health — your doctor will be able to advise you on these.

image8

The production man is adjusting the machine

The hospital uses our ultrasound bone densitometry examing

Package Size

One Carton

Size(cm): 61cm×58cm×49cm

G.W.20 Kgs

N.W: 20 Kgs

One Wooden Case

Size(cm): 68cm×64cm×98cm

G.W.40 Kgs

N.W: 32 Kgs

Packing

A1-packing-5
A1-packing-3
A1-packing-(2)
A1-packing-(7)
A1-packing-(4)
A1-packing-(5)
A1-packing-(1)
A1-packing-(8)


Product detail pictures:

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan detail pictures

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan detail pictures

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan detail pictures

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan detail pictures

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan detail pictures

Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan detail pictures


Related Product Guide:

The key to our success is "Good Products Good quality, Reasonable Value and Efficient Service" for Low price for Dual Energy X Ray Absorptiometry Definition - Bone Densitometer New BMD-A1 Assembly – Pinyuan , The product will supply to all over the world, such as: Sudan, Munich, Sevilla, Our objective is "to supply first step products and best service for our customers, thus we are sure you must have a margin benefit through cooperating with us". If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
  • This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Maxine from Malaysia - 2018.02.21 12:14
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Merry from azerbaijan - 2018.09.12 17:18