• s_banner

High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As for aggressive costs, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such high-quality at such rates we have been the lowest around for Bone Densitometer Price In Pakistan, Dual Energy X Ray Absorptiometry And Ultrasound In Clinical Practice, Dual Energy X Ray Absorptiometry Whole Body, We welcome an prospect to do enterprise along with you and hope to have pleasure in attaching even more aspects of our items.
High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan Detail:

Portable ultrasound bone densitometry BMD-A1 is for testing bone density. It can be used for diagnosing diseases, as well as for disease screening and physical examination of healthy people. Ultrasound bone densitometer is cheaper than DEXA bone densitometer, simple to operate, no radiation, high accuracy, less investment. A bone mineral density test, sometimes just called a bone density test, detects whether you have osteoporosis.

When you have the osteoporosis, your bones get weak and thin. They become more likely to break. Bone and joint pain and fractures caused by osteoporosis are common clinical diseases, such as deformation of the lumbar and back vertebrae, Disc disease, vertebral body fracture,cervical spondylosis, limb joint and bone pain, lumbar spine, femoral neck, radius fracture and so on. Therefore, bone mineral density examination is very necessary for the diagnosis and treatment of osteoporosis and its complications.

Main Function

Bone Densitometry is to measure the bone density or bone strength of the People’s radius and tibia. It is for Preventing osteoporosis.

Application

This portable model is the best choice for hospital outgoing examination, hospital wards, Mobile Inspection, Physical Examination Vehicle, Pharmaceutical factory, Pharmacy and Health Care Products promotion.

Application Range

Our Ultrasound Bone Densitometry always used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory, Pharmacy and Health Care Products Promotion.
The Department of the General Hospital, Such as

Pediatric Department,

Gynecology and Obstetrics Department,

Orthopedics Department,

Geriatrics Department,

Physical Examination Department,

Rehabilitation department,

Physical Examination Department,

Endocrinology Department.

Advantages

Ultrasound Bone Densitometry have low investment and benefit.

The advantages as following:

1. Low Investment.

2. High-usage.

3. Small limitation.

4. Fast return, no consumables.

5. High benefit.

6. Measurement parts: Radius and Tibia.

7. The probe adopts American DuPont technology.

BMD-A1-(3)

Measurement Parts: Radius and Tibia.

image8
BMD-A1-(1)
image9
image11

Operational Principle

image12

Main Feature

●Portable model, easy to move.

●Precise and Artistic Mould Manufactured.

●Full dry technology, makes diagnostic more convenient.

●Measurement parts: Radius and Tibia.

●The measurement process is simple and fast.

●It with different countries clinical database, including: European, American, Asian, Chinese.

●High measurement speed, short measurement time.

●High Measurement Accuracy.

●Good Measurement Reproducibility.

●The particular correction system to correct system error effectively.

●WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult).

●English menu and Color Printer report.

●CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility.

Technical Specifications

image1 Large Scale Integrated circuit

image2 Multi – layer circuit board design

image3 High shielding Multi-point Signal Contact Mode

image4 Precise brushed metal mould manufactured

image5 Famous Brand Embedded Industrial Control Computer

image6 Special Analysis System Based on Different Countries People

Bone Density Testing Results

Bone Density testing results will be in the form of two scores:

T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.

Here’s what the T score means:
● -1 and above: Your bone density is normal
● -1 to -2.5: Your bone density is low, and it may lead to osteoporosis
● -2.5 and above: You have osteoporosis

Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.
A Z score below -2.0 means that you have less bone mass than someone your age and that it could be caused by something other than aging.

Configuration

1. BMD-A1Ultrasound Bone Densitometer Main unit

2. 1.20MHz Probe

3. BMD-A1 Intelligent Analysis System

4. Calibrating Module (Perspex sample)

5. Disinfectant Coupling Agent

Note: the Notebook is Optional

One Carton

Size(cm): 40cm×40cm×40cm

G.W. :6 Kgs

N.W: 4 Kgs

BMD-A1-(2)

Bone Densitometry is to measure the bone density or bone strength of the People’s radius and tibia. It is for Preventing osteoporosis. Bone Mass Starts to lose irreversibly from 35 years old. A bone mineral density test, sometimes just called a bone density test, detects whether you have osteoporosis, It is measure how much calcium and minerals are in a part of your bone. The more minerals you have, the better. That means your bones are stronger, denser, and less likely to break. The lower your mineral content, the greater your chance of breaking a bone in a fall. Anyone can get osteoporosis.

When you have this condition, your bones get weak and thin. They become more likely to break. It’s a silent condition, which means you don’t feel any symptoms. Without a bone density test, you may not realize you have osteoporosis until you break a bone.

image14

Bone Health(left)                                                                                    Osteopenia(middle)                                                                                    osteoporosis(right)  

Packing

A1-packing-5
A1-packing-3
A1-packing-(2)
A1-packing-(7)
A1-packing-(4)
A1-packing-(5)
A1-packing-(1)
A1-packing-(8)


Product detail pictures:

High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan detail pictures

High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan detail pictures

High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan detail pictures

High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan detail pictures

High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan detail pictures


Related Product Guide:

Dedicated to strict high-quality management and considerate shopper company, our experienced team associates are normally available to discuss your requirements and ensure full shopper gratification for High reputation Bone Densitometry Definition - Portable Ultrasound Bone Densitometry BMD-A1 – Pinyuan , The product will supply to all over the world, such as: Zurich, UAE, Liverpool, Our company, is always regarding quality as company' s foundation, seeking for development via high degree of credibility , abiding by iso9000 quality management standard strictly , creating top-ranking company by spirit of progress-marking honesty and optimism.
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Gemma from Armenia - 2017.05.02 18:28
    The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Debby from Finland - 2017.11.01 17:04